Snapshot Details
- Product Type: Submersible Pump
 - Model Number: MTO
 - Power Supply Type: DC
 - Simulated PV Array Size [W]: 1500
 - Simulated Head Value [m]: 10
 - High Irradiance Day: Total Volume of Water Moved per Solar Day [m3/day]: 119.3
 
Product Information
- Brand 
Product brand name as listed on consumer-facing materials, such as product package, nameplate, or product specification sheet Simusolar
 - Product Type Submersible Pump
 - Model Number MTO
 - Power Supply Type DC
 - Manufacturer Simusolar Ltd.
 - Warranty [months] 24
 - Rated Controller Input Power [W] 1100
 - Rated Controller Input Voltage [V] 60-400
 - Battery Integrated [yes/no] No
 
Pump Information
- Pump Type Centrifugal jet
 - Motor Type Brushless DC
 - Pump Dimensions [L*W*H in cm] 7*7*72
 - Rated Head Range [m] 0-20
 - Rated Maximum Flow Rate [m3/h] 15.6
 - Rated Pump Ingress Protection (IP) Rating Not rated
 
Test Setup
- Simulated PV Array Size [W] 1500
 - Simulated Head Value [m] 10
 
Operating Range
- Minimum Irradiance Required to Start Pump [per 50W/m2] 
See test setup for simulated PV array size and head value used during testing 100
 - Maximum Head [m] 
See test setup for simulated PV array size and head value used during testing 22.7
 
Maximum Efficiency at 700W/m2
- Maximum Wire-to-Water Efficiency [%] Simulated at 700W/m2 
Simulating pump performance on a partly cloudy day (700W/m2 peak) 41%
 - Head Value at Maximum Efficiency [m] Simulated at 700W/m2 
Simulating pump performance on a partly cloudy day (700W/m2 peak) 12.9
 - Flow Rate at Maximum Efficiency [L/min] Simulated at 700W/m2 
Simulating pump performance on a partly cloudy day (700W/m2 peak) 179.7
 
Low Irradiance Day - Fully Cloudy (450W/m2 peak)
- Low Irradiance Day: Hydraulic Energy per Day [Wh/day] 
Simulating pump performance on a fully cloudy day (450W/m2 peak) 1203.8
 - Low Irradiance Day: Average Wire-to-Water Efficiency [%] 
Simulating pump performance on a fully cloudy day (450W/m2 peak) 32%
 - Low Irradiance Day: Total Volume of Water Moved per Solar Day [m3/day] 
Simulating pump performance on a fully cloudy day (450W/m2 peak) 44.2
 - Low Irradiance Day: Hours of Operation [h] 
Simulating pump performance on a fully cloudy day (450W/m2 peak) 7.2
 
Average Irradiance Day - Partly Cloudy (700W/m2 peak)
- Average Irradiance Day: Hydraulic Energy per Day [Wh/day] 
Simulating pump performance on a partly cloudy day (700W/m2 peak) 2250.7
 - Average Irradiance Day: Average Wire-to-Water Efficiency [%] 
Simulating pump performance on a partly cloudy day (700W/m2 peak) 33%
 - Average Irradiance Day: Total Volume of Water Moved per Solar Day [m3/day] 
Simulating pump performance on a partly cloudy day (700W/m2 peak) 82.6
 - Average Irradiance Day: Hours of Operation [h] 
Simulating pump performance on a partly cloudy day (700W/m2 peak) 9.8
 
High Irradiance Day - Full Sun (1000W/m2 peak)
- High Irradiance Day: Hydraulic Energy per Day [Wh/day] 
Simulating pump performance on a fully sunny day (1000W/m2 peak) 3214.8
 - High Irradiance Day: Average Wire-to-Water Efficiency [%] 
Simulating pump performance on a fully sunny day (1000W/m2 peak) 31%
 - High Irradiance Day: Total Volume of Water Moved per Solar Day [m3/day] 
Simulating pump performance on a fully sunny day (1000W/m2 peak) 119.3
 - High Irradiance Day: Hours of Operation [h] 
Simulating pump performance on a fully sunny day (1000W/m2 peak) 11.6
 
Product Quality Inspection
- Pump External Workmanship and Quality Evaluation [poor/satisfactory/good] Good
 - Pump Internal Workmanship and Quality Evaluation [poor/satisfactory/good] Good
 - Pump Safety Evaluation [poor/satisfactory/good] Good
 - Pump Operating Manual Evaluation [not included/poor/needs improvement/good] Good
 
Sampling and Testing Information
- Sample Location Manufacturer Warehouse
 - Retail Price [USD] N/A
 - Test Laboratory Name Schatz Energy Research Center
 - Test Completion Date [MM/DD/YYYY] 5/28/2019
 
Awards
- Global LEAP Awards Finalist (2019)