VeraSol
Snapshot Details
- Product Type: Pedestal Fan
 - Model Number: ECO AIR 16" UP
 - Size [measured, diameter in mm]: 380
 - Power Supply Type: DC
 - Nominal Conditions: Air Delivery [m3/min]: 35.32
 - Nominal Conditions: Power Input at Max Speed [W]: 7.9
 - Nominal Conditions: Energy Efficiency Value [m3/min/W]: 4.5
 - Retail Price [USD]: N/A
 
Product Information
- Brand 
 Product brand name as listed on consumer-facing materials, such as product package, nameplate, or product specification sheet NIWA - Product Type Pedestal Fan
 - Model Number 
 Model number as listed on consumer-facing materials, such as product package, nameplate, or product specification sheet ECO AIR 16" UP - Size [measured, diameter in mm] 380
 - Power Supply Type DC
 - Manufacturer 
 Name of the manufacturer NIWA Solar - Country of Manufacture 
 Country where the product is manufactured China - Warranty [months] 
 Duration of the consumer-facing product warranty that covers manufacturing defects under normal use 12 - Rated Input Power [W] 
 Required power input as specified by manufacturer 10 - Rated Input Voltage [V] 
 Required voltage input as specified by manufacturer 12 - Type of Plug or Connector Included with Product to Connect to Energy Supply 
 
Fan Features
- Number of Regulated Speeds 3
 - Timer No
 - Light No
 - Oscillation Yes
 - Oscillation Movement [degrees] 87
 - Vertical Angular Movement Yes
 - Vertical Angular Movement [degrees] 20
 - Height [cm] 102
 - Maximum Adjusted Height [cm] 123
 
Test Setup
- Test Voltage [V] 
 - Test Current [A] 
 - Test Setup Notes 
 
Nominal Conditions: Performance
- Nominal Conditions: Air Delivery [m3/min] 
 Amount of airflow delivered by the fan when set at maximum speed 35.32 - Nominal Conditions: Power Input at Max Speed [W] 
 Amount of power required to operate the product when the fan setting is at the highest speed 7.9 - Nominal Conditions: Energy Efficiency Value [m3/min/W] 
 Volume of airflow delivered by the product per Watt of input power Higher value means higher efficiency 4.5 - Nominal Conditions: Highest Regulated Speed [RPM] 960
 
Over-Voltage Conditions: Performance
- Over-Voltage Conditions: Air Delivery [m3/min] 
 Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 38.73 - Over-Voltage Conditions: Power Input at Max Speed [W] 
 Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 11.2 - Over-Voltage Conditions: Energy Efficiency Value [m3/min/W] 
 Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 3.45 - Over-Voltage Conditions: Highest Regulated Speed [RPM] 
 Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 1093 
Under-Voltage Conditions: Performance
- Under-Voltage Conditions: Air Delivery [m3/min] 
 Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 31.19 - Under-Voltage Conditions: Power Input at Max Speed [W] 
 Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 5.4 - Under-Voltage Conditions: Energy Efficiency Value [m3/min/W] 
 Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 5.78 - Under-Voltage Conditions: Highest Regulated Speed [RPM] 
 Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 822 
Post Environment Conditions: Performance
- Post Environment Conditions: Air Delivery [m3/min] 
 Measured after the product is exposed to 40°C ± 2°C temperature and 93% ± 3% relative humidity for a minimum of 24 hours prior to testing 36.17 - Post Environment Conditions: Power Input at Max Speed [W] 
 Measured after the product is exposed to 40°C ± 2°C temperature and 93% ± 3% relative humidity for a minimum of 24 hours prior to testing 8 - Post Environment Conditions: Highest Regulated Speed [RPM] 
 Measured after the product is exposed to 40°C ± 2°C temperature and 93% ± 3% relative humidity for a minimum of 24 hours prior to testing 973 
Ingress Protection
- Ingress Protection Rating [IP number] 
 Rates the effectiveness of the sealing of electrical enclosures against intrusion from foreign bodies (eg fingers, tools, dirt, etc) IP20 - IP Test Results [Pass/Fail] Pass
 - Notes About Ingress Protection Product passed IP20 but failed IP30.
 
Drop Test
- Is there any damage to the motor after the drop test? No
 - Is there any damage to the fan blade after the drop test? No
 - Is there any damage to the fan guard after the drop test? Yes
 - Is there any damage to the on/off switch after the drop test? No
 
Overall Product Quality Inspection
- Is the fan fitted with two or more well-balanced blades made from metal or other suitable material so as to be reasonably free from vibration? Yes
 - Are the bearings of good quality and lubricated appropriately for use? Yes
 - Is there an automatic shutdown mechanism when fan blades are impeded? No
 - Is the fan clearly marked with a standard nameplate? Missing serial number
 - Notes About Nameplate Yes
 - Does the fan's packaging include appropriate information? Missing gross weight, package dimensions and date of manufacture
 - Notes About Packaging Yes
 - Does the fan come with appropriate documentation? N/A
 - Notes About Documentation Yes
 - Are the fan blades appropriately guarded in accordance with Clause 20.101 of "IEC 60335-2-80: Household and similar electrical appliances. Safety. Particular requirements for fans."? Yes
 
Off-Grid Compatibility
- Does the fan have its own low voltage disconnect (LVD) & reconnect (LVR) circuit or similar automatic shutdown mechanism to protect batteries from unintended drainage? Yes
 - Notes About LVD and LVR Fan shut down automatically when input voltage was reduced to 9.5 V
 - Is the LVD/LVR/timer function adequately described in the user manual or product packaging? No
 
Sampling And Testing Information
- Sample Location Manufacturer Warehouse
 - Retail Price [USD] N/A
 - Test Completion Date [MM/DD/YYYY] 12/13/2019
 - Test Laboratory Name TUV SUD Hong Kong
 
Awards